Opportunities to Do Business with the Universities

Construction Solicitations to Prequalify Contractors

Full Details

 Institution NC State University 
 Institution URL for Additional
Information about this Project (Optional)
 http://www.ncsu.edu/facilities/advertisements/index.htm 
 Project Name Facilities Operations Support Building - Centennial Biomedical Campus 
 Prequalifying for 
North Carolina State University is seeking qualification statements from general contractors for renovations to the Facilities Operations Support Building located at 1528 Blue Ridge Road on NC State's Centennial Biomedical Campus. This project consists of the renovation of a 14,577 gsf building for shop space, offices, and materials storage, as well as exterior site development which will include storage buildings for vehicles and equipment; bulk storage bins, and hazmat storage. New work will include roofing and insulation, new interior partitions, doors, lighting, finishes, HVAC, sprinkler system modifications, electrical, telecom, and security. To qualify, the contractor must have a general contractor's license in the State of North Carolina as well as meet applicable bonding requirements. The contractor must show comparable work experience, both in complexity and dollar value, and preferably in a University campus environment, to the scope of work outlined above. NC State University has an affirmative policy of fostering, promoting, and conducting business with women and minority owned enterprises. Women and minority contractors are encouraged to participate in the prequalification process.
 
 Main Contact for Submission Campus Contact 
 Name of Design Firm DTW Architects 
 Design Firm Contact Name Robert Sotolongo 
 Design Firm Telephone Number (919) 317-4020 
 Design Firm Email rsotolongo@dtwarch.com 
 CM at Risk Firm Name  
 CM at Risk Firm Email  
 Campus Contact Email wrdavis3@ncsu.edu 
 Due Date 09/05/2013 
 Due Time 5:00 pm 
 Submit To 
To be considered, the contractor must obtain an application package from the NC State University Project Manager and submit a sealed, fully completed qualification document by 5:00 pm, September 5, 2013, to Bill Davis, project manager, at Administrative Services Building III, 2701 Sullivan Dr., Suite 331, NCSU, Campus Box 7520, Raleigh, NC 27695-7520. Please contact the project manager via email (preferred) or phone to request a package. Three (3) hard copies of completed qualification packages must be submitted to the project manager. Completed qualification packages will not be accepted electronically.